Get Instant Access of 100% Real HP HPE6-A66 Exam Questions with Verified Answers
Exam Dumps for the Preparation of Latest HPE6-A66 Exam Questions
NEW QUESTION # 20
A company has chosen an Aruba mobility controller solution for the redesign of their wireless network The design will have two 7205 controllers in a cluster for campus employees and a single VMC-50 virtual controller for remote access via a DMZ. A Mobility Master (MM) is used for centralized license and controller management. All controllers will minimally run ArubaOS 8 4 or later Currently the company has 1.000 employees. There are 30 branch offices that will use RAPs to connect to the DMZ controller. A peak of 100 users concurrently using the VIA client will also connect to the DMZ controller.
How many Aruba LIC-VIA licenses does the company need to purchase for this solution?
- A. 1,030
- B. 0
- C. 1
- D. 2
Answer: A
NEW QUESTION # 21
A network architect is redesigning the access layer in a data center for a customer. The access layer requires fixed-port switches that support VSF and data center features like L2 VXLAN and REST-API Which switching solution should the network architect recommend?
- A. 0
- B. 3810M
- C. 2930F
- D. 1
Answer: C
NEW QUESTION # 22
Which feature does the Aruba AP 555 support? (Select two.)
- A. high density indoor locations
- B. desk wall plate mounted
- C. 802.11ac and lower standards only
- D. weather proof and temperature hardened
- E. three radios
Answer: A,C
NEW QUESTION # 23
Refer to the exhibit.
When planning the use of Cat7 cabling for a SmartRate connection between an ArubaOS AP and an ArubaOS switch, which sections should be considered when calculating distance?
- A. A + B + C + D
- B. A + B
- C. A + B + C
- D. A + C
Answer: A
NEW QUESTION # 24
A network architect is given the task to design a new network solution for NewStellar Company, Inc. NewSteiiar has a main corporate campus in a business park with two adjacent buildings. The network architect has given one floor to analyze, Building 1 Floor 2, shown in the attached exhibit.
Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235 square meters) total, which results in a total of 338,100 feet (31,410 square meters) for the entire building space. Each floor has a central main corridor with washrooms, stairs, elevators and supply and network cabinets. There are cubicles around the perimeter of the floor. The central part main corridor's dimensions contain 9,350 square feet {870 square meters).
Because of security concerns, video cameras will be installed throughout the facility. There are 16 of these per floor, 8 per wiring closet. The cameras are non-WiFi capable and require POE 802.3af-capable switch ports from which to draw power.
A wireless capacity design is required. Assuming that wireless coverage is required across the Building 1, Floor 2, including the central area, and that half the required APs will connect to each wiring closet, approximately how many POE+ ports will be required per wiring closet for all devices that have POE or POE+ needs?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
NEW QUESTION # 25
A company needs to replace an existing legacy wireless and wired solution with one that supports features like 802 11 ax for APs and logical switching for switches. The company is located on a single floor with two wiring closets. Assume that there will be 10 APs connected via POE+ to each wiring closet, along with 36 wired user connections All switches on a floor should be configured in a single stack. The distance between wiring closets is 100 feet (31 meters).
Which switching solution will minimally provide 10 Gbps uplinks at the most cost-effective price, while still meeting the company's requirements?
- A. 3810M switches
- B. 2930M switches
- C. 5406R switches
- D. 2930F switches
Answer: B
NEW QUESTION # 26
A customer requires Aruba switches that support Smart Rate ports to connect to Aruba APs Which switching product should the customer purchase that will provide 24 Smart Rate ports per access layer switch'?
- A. Aruba 2930F
- B. OfficeConnect 1950
- C. Aruba 2930M
- D. Aruba 2540
Answer: C
NEW QUESTION # 27
A network architect is creating a new wired design for a warehouse building. As a best practice, what length should the architect allow for the service loop in the wiring closets in this environment?
- A. 3 feet (1 m)
- B. 15-30 feet (5-10 m)
- C. 3-10 feet (1-3 m)
- D. 30-60 feet (10-20 m)
Answer: A
NEW QUESTION # 28
A customer is purchasing Aruba 555 APs for a new wireless network. The APs will be pre-staged as campus APs (CAPs) and be managed by a controller solution During the pre-staging process, console access to the APs might be necessary Which console connection cable should the customer purchase for the 555 APs?
- A. USB-A
- B. RJ-45
- C. RS-232
- D. Micro-B USB
Answer: D
NEW QUESTION # 29
A customer placed an order for an ArubaOS 5406R switch and plans to rack mount it in a wiring closet. The dimensions of the switch are 17.5 inches wide (44.45 cm), 6.9 inches high (17.5 cm), and 17.75 inches deep (45.1 cm). How many rack units should a customer plan for this switch?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
NEW QUESTION # 30
A network architect is designing a new wireless solution for a company The company needs seamless roaming and client and AP active load balancing. The company also requires an Aruba Mobility Master (MM) to manage the wireless infrastructure. Which Aruba feature does the architect need to include in the design?
- A. Client Match
- B. IAP VC
- C. AirMatch
- D. Clustering
Answer: D
NEW QUESTION # 31
A customer has over 100 access layer switches. The customer requires user authentication done via the Aruba Dynamic Segmentation feature. What components are required to implement this solution? (Select two.)
- A. Aruba APs
- B. AirWave server
- C. Aruba mobility controller
- D. Active Directory server
- E. enterpnse authentication server
Answer: B,C
NEW QUESTION # 32
What is the main key for a network design to ensure users have a good experience running their applications'?
- A. Provide appropriate AP density.
- B. Provision adequate bandwidth.
- C. Implement appropriate security controls
- D. Determine the number of users per location.
Answer: A
NEW QUESTION # 33
A high-end theater venue will be implementing an Aruba wireless solution using ceiling- and wall-mounted APs. The venue wants to ensure the the APs blend into the ceiling and wall environments. What solution should the customer use to ensure that wireless coverage is not hampered?
- A. Place a strip of tape over the LEDs
- B. Place the APs above the ceiling and behind the walls
- C. Paint the APs to match the ceilings or walls
- D. Order Aruba AP covers for the APs
Answer: B
NEW QUESTION # 34
A network architect is doing a site survey for a new wireless design One concern the company has with the old wireless network is coverage. In some cases, APs would lose power and some employees in the network would lose wireless connectivity. The new design needs to prevent this issue from occurring. During the site survey, what are best practices to be followed in regards to the dBm signal level and the power of the AP to ensure adequate wireless coverage and minimal overlap of AP signals for the new design?
- A. AP power at 100% and a measurement of -65 dBM on the measuring device
- B. AP power at 75% and a measurement of -80 dBM on the measuring device
- C. AP power at 50% and a measurement of -65 dBM on the measuring device
- D. AP power at 75% and a measurement of -90 dBM on the measuring device
Answer: A
NEW QUESTION # 35
A customer requires a campus core virtualization solution that supports a dual control and management planes, as well as active-active forwarding paths. Which solution would meet the customer's requirements?
- A. Mesh stacking
- B. VSF
- C. VSX
- D. Backplane stacking
Answer: D
NEW QUESTION # 36
A network architect is designing a new Wi-Fi solution for a small university The solution will involve two mobility controllers that will be clustered at the campus core Because students use a lot of video in both the dormitory rooms and in the classrooms, the solution will need to support 50Gbps via link aggregation between the controllers and core switches.
Which solution would most cost-effectively meet this requirement for the campus core?
- A. Aruba 7220 mobility controllers and 3810M switches
- B. Aruba 7280 mobility controllers and 5406R switches
- C. Aruba 7240XM mobility controllers and 3810M switches
- D. Aruba 7210 mobility controllers and 5406R switches
Answer: A
NEW QUESTION # 37
A network architect is creating a new wireless solution for a customer. Wireless coverage is required throughout all four floors of two buildings on the same campus. Dynamic RF capabilities, including AirMatch, are required. Seamless roaming is required within and between the two buildings. Each floor will have approximately 20 APs and 6 external APs are required for connectivity between the two buildings.
- A. Two 7205 mobility controllers in a cluster
- B. Given this information, which Aruba solution would be the most cost-effective while still meeting the customer's requirements? O An IAP cluster per floor
- C. Two 7030 mobility controllers in a cluster
- D. A standalone 7008 controller per floor
Answer: B
NEW QUESTION # 38
Which IRIS option will automatically create a project with a blank preconfigured Site-1 ?
- A. New Project
- B. New Express Mode
- C. New Campus
- D. New Site
Answer: C
NEW QUESTION # 39
A customer is designing a new wired network. The customer requires 50 Gbps uplinks, VSF logical switching, and smart rate port support Which of the following switches would meet these requirements?
- A. 8300 series
- B. 6300 series
- C. 5400R series
- D. 3810M series
Answer: D
NEW QUESTION # 40
A network architect has developed a design for a new Aruba Wi-Fi network that will include a virtual Mobility Master (MM) running the ArubaOS 8.4 operating system that will manage:
* Two clustered 7210 controllers with 600 campus APs
* Two clustered VMC-50 controllers with 75 remote APs
* Wireless IPS
The architect plans on creating user roles and firewall policies on the controllers as well as implementing AirMatch. What would meet the license requirements for this scenario?
- A. LIC-MM-VA-50 (X1), LIC-MC-VA-50 (x2). LIC-AP (X675), PEF (x675), RFP (X675)
- B. LIC-MM-VA-1000 (X1). LIC-MC-VA-50 (X1), LIC-AP (x675). PEF (X675), RFP (X675)
- C. LIC-MM-VA-1000 (X1), LIC-MC-VA-50 (x2), LIC-AP (X675). PEF (X675). RFP <x675)
- D. LIC-MM-VA-1000 (X1), LIC-MC-VA-50 (x1), LIC-AP (x600). PEF (X600), RFP (x600)
Answer: B
NEW QUESTION # 41
A network architect wants to estimate the number of Aruba APs that will be needed Tor a new wireless design and determine the wireless coverage using VisualRF. The company requires a high-density design. The building has 200.000 square feet. How many APs should the network architect add to VisualRF in order to perform the coverage analysis?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION # 42
Which type of Aruba AP uses its radio as its back-haul connection?
- A. Air Monitor (AM)
- B. Mesh Porta
- C. Remote AP (RAP)
- D. Mesh Point
Answer: B
NEW QUESTION # 43
NewRocket requires a wireless capacity design 30 Aruba 510 APs will be connected to each wiring closet using SmartRate connections. Wireless coverage needs to be provided even if a POE+ switch loses power Because of security concerns, wired video cameras were recently installed throughout the facility. There are 12 of these per floor. 6 per wiring closet. The cameras are 802.11n WiFi capable and have power injectors from which to draw power.
Based on the POE+ needs of the mentioned devices, which solution would meet the POE+ requirements while still providing a redundant and cost-effective Wi-Fi solution for the devices that require POE+ for Building 1, Floor 2?
- A. One 2930M 48-port POE+ switch
- B. Two 2930F 24-port POE+ switches
- C. Two 2930M 24-port POE+ switches
- D. One 3810M 40G 8 HPE Smart Rate switch
Answer: A
NEW QUESTION # 44
......
HP HPE6-A66 (Aruba Certified Design Associate) Exam is a certification exam designed for professionals looking to validate their skills and knowledge in designing Aruba wireless networks. HPE6-A66 exam is intended for network architects, engineers, and consultants who seek to design solutions for small to medium-sized businesses and enterprise networks.
Download Latest & Valid Questions For HP HPE6-A66 exam: https://torrentlabs.itexamsimulator.com/HPE6-A66-brain-dumps.html

