Cisco 350-601 exam is a core exam for the Cisco Certified Specialist - Data Center Core certification, and it is also a requirement for the Cisco Certified Internetwork Expert Data Center (CCIE Data Center) certification. 350-601 exam is intended for IT professionals with experience in implementing and managing data center technologies.
NEW QUESTION # 257
Which configuration generates a syslog message when CPU utilization is higher than 60%?
- A. event manager applet HIGH-CPU
event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op gt 60 poll-interval 5 action 1.0 syslog priority notifications msg "cpu high" - B. event manager applet HIGH-CPU
event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type next entry-op gt 60 poll-interval 5 action 1.0 syslog priority notifications msg "cpu high" - C. event manager applet HIGH-CPU
event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type next entry-op lt 60 poll-interval 5 action 1.0 syslog priority notifications msg "cpu high" - D. event manager applet HIGH-CPU
event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op lt 60 poll-interval 5 action 1.0 syslog priority notifications msg "cpu high"
Answer: A
Explanation:
Explanation
https://www.cisco.com/c/en/us/support/docs/ip/internet-protocol-ip/200931-EEM-Subsystem-in-Order-to-Monitor-CPU-Tr.pdf
https://blog.ipspace.net/2008/06/generate-snmp-trap-on-high-cpu-load.html
NEW QUESTION # 258
A storage engineer must configure zoning on a Cisco MDS 9000 Series switch. Drag and drop actions from the left into the order on right
Answer:
Explanation:
Explanation
Graphical user interface, table Description automatically generated with medium confidence

https://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/sw/6_2/ configuration/guides/fabric/nx-os/nx_os_fabric/zone.html
NEW QUESTION # 259
An engineer must configure a named VSAN when the fabric interconnect is in Fibre Channel switch mode The VSAN must meet these requirements:
* Named VSAN must be called "VSAN 10".
* VSAN ID must be 10.
* FCoE ID must be 20.
* VSAN 10 must be attached to port 2 in slot 1.
Which command set configures a VSAN when the fabric interconnect is in Fibre Channel switch mode?
- A. Option B
- B. Option D
- C. Option C
- D. Option A
Answer: D
NEW QUESTION # 260
Which statement describes monitoring Fibre Channel traffic on a Cisco UCS 6332 Fabric Interconnect?
- A. The monitoring of Fibre Channel traffic is limited to the default VSAN.
- B. Fibre Channel traffic is monitored only on one vHBA per server.
- C. The destination port for monitoring must be an unassigned Fibre Channel port.
- D. Fibre Channel traffic is capable to be monitored as it is encapsulated as FCoE.
Answer: B
Explanation:
You can monitor Fibre Channel traffic using either a Fibre Channel traffic analyzer or an Ethernet traffic analyzer. When Fibre Channel traffic is monitored with an Ethernet traffic monitoring session, at an Ethernet destination port, the destination traffic is FCoE. The Cisco UCS 6300 Fabric Interconnect supports FC SPAN only on the ingress side. A Fibre Channel port on a Cisco UCS 6248 Fabric Interconnect cannot be configured as a source port.
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/System- Monitoring/3-2/b_UCSM_GUI_System_Monitoring_Guide_3_2/ b_UCSM_GUI_System_Monitoring_Guide_3_2_chapter_01101.pdf
NEW QUESTION # 261 
Refer to the exhibit. The Cisco Nexus Series Switches SW1, SW2, and SW3 are connected via Layer 2 copper interfaces. An engineer implements loop prevention standard IEEE 802.1w on each VLAN lo provide lasier recovery from network changes or failures. The Implementation has these requirements
* Interfaces that are connected to Layer 2 hosts must not receive STP BPDUs.
* The implementation must detect unidirectional links due to one-way traffic twisted-pair links
* Bridge assurance must be enabled between SW2 and SW3
* The Layer 2 domain must be protected from superior BPDUs that arrive from external switches.
Drag and drop the code snippets from the right onto the blanks in the code on the left to complete the configuration for SW3. Not all code snippets are used.
Answer:
Explanation:
Explanation
Network
Aggressive
Bpdu
edge
NEW QUESTION # 262
Which two authentication types does Cisco UCS Manager support when configuring authentication? (Choose two.)
- A. LDAP
- B. 802.1X
- C. local
- D. Kerberos
- E. PAM
Answer: A,C
NEW QUESTION # 263
Drag and drop the characteristics from the left onto the NAS protocols on the right. Some characteristics are used more than once
Answer:
Explanation:

NEW QUESTION # 264
What are two requirements when planning a Cisco HyperFlex All Flash standard cluster installation using three HX240c M5 servers? (Choose Two)
- A. The servers must be discovered, unassociated, and connected to each fabric interconnect.
- B. The cluster deployment type must support a mix of HDD and SSD.
- C. The hypervisors must be installed to Cisco FlexFlash SD cards.
- D. If the Jumbo MTU option in the HyperFlex installer is enabled, then jumbo frames must also be enabled on the upstream switches.
- E. If the Jumbo MTU option in the HyperFlex installer is enabled, then jumbo frames do not have to be enabled on the upstream switches.
Answer: A,D
Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/hyperconverged_systems/HyperFlex_HX_DataPlatformSoftware/ AdminGuide/3_5/ b_HyperFlexSystems_AdministrationGuide_3_5/b_HyperFlexSystems_AdministrationGuide_3_5_chapter_0111
NEW QUESTION # 265
Refer to the exhibit.
An engineer configures a new application profile using REST API and receives this error massage. Which method can be used before application profile can be configured?
- A. POST to aaaRefresh
- B. POST to aaaLogin
- C. POST to aaaLogout
- D. GET to aaaListDomains
Answer: B
NEW QUESTION # 266
An engineer is implementing NetFlow on a Cisco Nexus 7000 Series Switch. Drag and drop the NetFlow commands from the left into the correct order they must be entered on the right.
Answer:
Explanation:
NEW QUESTION # 267
What are two types of FC/FCoE oversubscription ratios? (Choose two.)
- A. host bandwidth to storage bandwidth
- B. edge ISL bandwidth to core ISL bandwidth
- C. server storage to end-node count
- D. port bandwidth to uplink bandwidth
- E. switch processing power to end-node processing power
Answer: A,B
Explanation:
https://www.ciscolive.com/c/dam/r/ciscolive/us/docs/2017/pdf/BRKDCN-1121.pdf
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/operations/n5k_fcoe_ops.html
NEW QUESTION # 268
Where is the witness deployed in a two-node Cisco HyperFlex Edge deployment?
- A. to a third-party cloud provider
- B. to Cisco Intersight
- C. to the HyperFlex Edge two-node cluster
- D. to an additional server with network access to HyperFlex Edge
Answer: B
Explanation:
Section: Compute
NEW QUESTION # 269
Refer to the exhibit.
Which statement about the ERSPAN configuration in this environment is true.
- A. Host A is the source of ERSPAN spanned traffic and host B is the traffic analyzer.
- B. Host B is the source of ERSPAN spanned traffic and host A is the traffic analyzer.
- C. The session number of the source of ERSPAN spanned traffic must have a session ID of 47 for the traffic analyzer to receive the traffic.
- D. The session number of the source of ERSPAN spanned traffic must have a session ID of 48 for the traffic analyzer to receive the traffic.
Answer: A
NEW QUESTION # 270
An engineer is seeking the most optimal on demand CPU performance while configuring the BIOS settings of a UCS C-series rack mount server.
What setting will accomplish this goal?
- A. C2 state
- B. C6 Retention
- C. C0/C1 state
- D. C6 non-Retention
Answer: B
Explanation:
Section: Compute
NEW QUESTION # 271
An engineer is using REST API calls to configure the cisco APIC. Which data structure must be used within a post message to receive a login token?
A)
B)
C)
D)
- A. Option D
- B. Option A
- C. Option C
- D. Option B
Answer: D
NEW QUESTION # 272
APIC EPG Resolution Immediacy is set to "Immediate" Which statement is true about the Deployment Immediacy for VMM domains associated to EPGs?
- A. If "immediate" is selected the policy is programmed in the hardware as soon as the leaf is booted.
- B. If "On demand" is selected the policy is programmed in the hardware only when the first packet is received through the data path.
- C. If "On demand" is selected, the policy is programmed in the hardware only when the APIC detects a VM created in the EPG.
- D. The "Immediate" and "On demand" options require a port group to be created on the VDS.
Answer: B
NEW QUESTION # 273
Which statement about the MAC address that the FCoE Initialization Protocol chooses for use by an E-Node in an FCoE implementation is true?
- A. The FCoE Initialization protocol uses a 24-bit FC-MAP and concatenates a 24-bit Fibre Channel ID to create a fibric-provided MAC address.
- B. The FCoE Initialization Protocol uses 01.00.0C as the first 24 bits of the MAC address and appends a
24-bit Fibre Channel ID to derive a full 48-bit FCoE MAC address. - C. The FCoE Initialization Protocol uses the burned-in MAC address of the converged network adapter for all FCoE operations.
- D. FCoE does not use a MAC address. The FCoE Initialization Protocol is used to acquire a Fibre Channel ID, and the address is used for all FCoE communications in the same way as Fibre Channel Protocol.
Answer: A
Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/solutions/Enterprise/Data_Center/UF_FCoE_final.html#wp1154912
NEW QUESTION # 274
......
Concluding Thoughts
A look at the latest IT trends shows that data centers are fast gaining popularity. Reputable companies are now hiring competent individuals to supervise the associated processes. That list includes data center project managers, data center engineers, compliance officers, and cybersecurity specialists just to mention a few. If you are looking for one of the easiest ways to keep pace with the latest trends, the new Cisco 350-601 exam is the way to go. This is the perfect time to capitalize on those opportunities!
Download Real Cisco 350-601 Exam Dumps Test Engine Exam Questions: https://torrentlabs.itexamsimulator.com/350-601-brain-dumps.html